API 6A WELLHEAD AND XMASS THREE DESIGN
EQUIPMENT TO MARKING LOCATION AND CRITERIA
Ø Equipment Marking
a. Marking Requirement
Minimum requirement for marking consist of temperature
rating, material class, product specification level, performance requirement
level, date of manufacture (month and year) and manufacturer’s name or mark (ISO
10423)
1. Marking method: Marking should have using
low-stress (dot, vibration or rounded V)
2. Nameplates: Nameplates is not required if the
information is permanent
3. Hidden marking: Stamped in a visible location.
4. Thread marking: The thread type marking (ISO 11960):
- Line
pipe: LP
- Casing
(short thread): STC
- Casing
(long thread): LC
- Casing
(buttress): BC
- Casing
(extreme line): XL
- Tubing
(non-upset): NU
- Tubing
(external-upset): EU
5. Size marking: The marking of size shall include
the nominal size.
6. Weld metal
overlay: Metal overlaid corrosion-resistant mark with “CRA”
to designate a corrosion-resistant alloy, or “SST” to designate an austenitic stainless steel.
7. Hardness tests: Mark with actual value of the
hardness test.
8. Other end connectors
- Other
end connectors marked with “OEC”
and than size or pressure rating.
- Hub
end connectors marked with "ISO
13533" and than size and pressure rating.
b. Wellhead equipment
Specify in Tables 27
and 28. The bore size shall be preceded by the word “Bore”.
c. Connectors and fittings
Show in tables 27
and 29.
d. Casing and tubing hangers
1. Marking of mandrel
hangers: Top and bottom threads listed with the bottom first. Specify in Tables 27 and 30.
2. Marking of slip
hangers: Hanger will be installed in upside down shall have the word DOWN.
(Showing in Tables 27 and 30)
e. Valves and Chokes
Specify in Tables
27 and 31.
- Marking for multiple valves: Designated
by the nominal bore sizes in decreasing (e.g. 3 1/16, 2 1/16, 2 9/16, 2
9/16). For equal bore sizes use the nominal bore size followed by the
number of bores (e.g. 2 1/16 Quad).
- Valve hand wheels: Mark with
direction of movement for opening the valves.
- Nominal size and maximum orifice for
chokes: marked as specified in 10.9.3.3.
- Choke beans: specified in Table 32.
- Valves prepared for actuators: Mark
the letter “V” after “ISO 10423”.
- Surface and underwater safety valves:
Marked with the letters “SSV” or “USV” following “ISO 10423”.API
Specification 6A / ISO 10423 103
f. Loose connectors [flanged, threaded, other end
connectors (OEC) and welded
Marking and stamping for all loose connectors specified in
Table 27.
g. Other equipment
- Actuators
Actuators shall be marked as specified in Table 27.
- Assemblies
of actuators and valves prepared for actuators
Valves prepared for actuators if assembled with the
actuator, mark as specified in Table 34.
- Ring
gaskets
Mark as
specified in Table 33. Ring gasket material shall be identified by the
following marks
h. Studs and Nuts
·
Stud Marking: Mark in conformance with ASTM A 193, ASTM A 320, or ASTM A 453. CRA material studs shall
be metal-stamped with the UNS
numbering.
- Nut
Marking: Marked in conformance with ASTM A 194.
- Impact
Test Marking: The impact test temperatures stamped directly under the
“CRA” marking.
i. Christmas trees
Assembled Christmas trees shall
be tagged with the information as specified in Table 34.
j. Valve-removal plugs
Marking with "ISO 10423" followed by the nominal
size and "VR" for 69,0 MPa (10 000 psi) working pressure or
"HPVR" for 138,0 MPa (20 000 psi) working pressure, material class
and manufacturer's name mark as a minimum.
k. Bullplugs
Marking with "ISO 10423" followed by the nominal
size, material class and manufacturer's name mark as a minimum.
l. Back-pressure valves
Marking with "ISO 10423" followed by the nominal
size, working pressure, material class and manufacturer's name mark as a
minimum.
Ø
Storing and shipping
- Draining
after testing: All equipment shall be drained and lubricated after
testing
·
Rust prevention: Shall have exposed
metallic surfaces protected with a rust preventative which will not become
fluid and run at a temperature less than 50 °C (125 °F).
- Sealing
surface protection: Must be
protected from mechanical damage for shipping.
- Assembly
and maintenance instructions: Specified in Annex H.
- Ring
gaskets: Must be boxed or wrapped during shipping and storage.
- Age
control of non-metallic materials
- PSL 1 and PSL 2
Shall be documented by the manufacturer.
- PSL 3 and PSL 4
Minimum provisions for non-metallic sealing materials:
- Maximum temperature not to
exceed 49 °C (120 °F)
- Indoor storage
- protected
from direct natural light
- stored
unstressed
- stored
away from contact with liquids
- Protected
from ozone and radiographic damage.
- The manufacturer shall define the provisions and requirements.